Ningbo Songee Hydraulic Technology Co., Ltd.
Products
Top View
  • No recommended products available at the moment.
SV-12-2 NCP Normally Closed Pilot-Operated Cartridge Solenoid Valve
The SV-12-2 NCP is a two-way, two-position, normally closed, pilot-operated cartridge solenoid valve. It is designed for high-flow hydraulic circuits and installs in a 12-2 cavity.

Service Online:

  • Overview

The SV-12-2 NCP is a normally closed, two-way, two-position pilot-operated cartridge solenoid valve designed for high-pressure hydraulic flow control.

The poppet-type construction provides reliable sealing and zero internal leakage. Its compact cartridge structure is suitable for installation in hydraulic manifolds, power units and mobile or industrial hydraulic systems.

Operating Principle

When the solenoid is de-energized, the valve functions as a check valve, allowing free flow from port 2 to port 1 while blocking flow from port 1 to port 2.

When the solenoid is energized, the pilot mechanism lifts the poppet and opens the controlled flow path from port 1 to port 2.

Manual Override

An optional manual override allows the valve to be operated without electrical power. Push the override button in, turn it counterclockwise and release it to hold the valve open.

To return the valve to normal operation, push the button in, turn it clockwise and release it.

Main Features

  • Normally closed hydraulic solenoid valve
  • Two-way, two-position operation
  • Pilot-operated poppet construction
  • Check-valve function when de-energized
  • Zero internal leakage
  • Maximum operating pressure of 250 bar
  • Optional manual override
  • Continuous-duty solenoid coil
  • Compact cartridge design for manifold installation
  • Aluminum or steel body options

Core Technical Data

Model SV-12-2 NCP
Valve Type Normally closed, two-way, two-position
Operating Method Pilot-operated solenoid control
Maximum Operating Pressure 250 bar
Internal Leakage 0 drops/min at 250 bar
Operating Temperature -30°C to +120°C
Coil Rating Continuous duty from 90% to 110% of rated voltage
Recommended Filtration ISO 16/12 for critical applications; ISO 19/15 for non-critical applications
Compatible Fluid Mineral-based hydraulic fluid
Aluminum Body Rating Anodized 6061-T6 aluminum alloy rated for 207 bar
Steel Body Rating Steel rated for 350 bar
Cavity 12-2

Typical Applications

  • Hydraulic manifold blocks
  • Hydraulic power units
  • Hydraulic cylinder control circuits
  • High-pressure flow isolation
  • Industrial automation equipment
  • Mobile hydraulic machinery
  • Material-handling systems
  • Hydraulic circuits requiring zero leakage

Install the solenoid coil with the identification lettering facing upward. Specifications are subject to change without notice.