Ningbo Songee Hydraulic Technology Co., Ltd.
Products
Top View
  • No recommended products available at the moment.
Lift Table Power Unit
AC hydraulic power units for large and compact lift tables, with solenoid-controlled lowering. Catalog configurations include 220VAC and 380VAC motors.

Service Online:

  • Overview

Large Lift Tables

Introduction

This power unit is designed for large lift tables. It consists of a high-pressure gear pump, AC motor, multifunctional manifold, valves and tank. Lowering is activated by the solenoid valve, and lowering speed is controlled by an adjustable throttle valve.

External Dimension Drawing

Lift Table Power Unit external dimension drawing - Large Lift Tables
External dimensions (mm). Click the drawing to view the full-size image.

Working Principle

Lift Table Power Unit hydraulic circuit - Large Lift Tables
Hydraulic circuit diagram.

Model and Specifications

Model Motor Voltage Motor Power (kW) Rated Speed (rpm) Pump Displacement (ml/rev) System Pressure (MPa) Tank Capacity (L) Solenoid Valve Voltage L (mm)
YBZ5-F2.5E3H2/LCCAG1 220VAC 2.2 2850 2.5 18 12 12VDC 677
YBZ5-E3.2F3H2/LCCBG1 220VAC 2.2 2850 3.2 14 14 24VDC 727
YBZ5-D3.7G3H2/LCCCG1 220VAC 2.2 2850 3.7 12 16 24VAC 777
YBZ5-E3.7G4I2/LCCDG1 380VAC 3 2850 3.7 16 16 110VAC 777
YBZ5-E4.2H4I2/LCCEG1 380VAC 3 2850 4.2 15 20 220VAC 877
YBZ5-D5J4I2/LCCEG1 380VAC 3 2850 5 12 25 220VAC 1002

Compact Lift Tables

Introduction

This power unit is designed for lift tables and integrates a high-pressure gear pump, AC motor, multifunctional manifold, valves and tank. Starting the motor raises the platform. Lowering is activated by the solenoid valve, with lowering speed regulated by the pressure-compensated flow control valve.

External Dimension Drawing

Lift Table Power Unit external dimension drawing - Compact Lift Tables
External dimensions (mm). Click the drawing to view the full-size image.

Working Principle

Lift Table Power Unit hydraulic circuit - Compact Lift Tables
Hydraulic circuit diagram.

Model and Specifications

Model Motor Voltage Motor Power (kW) Rated Speed (rpm) Pump Displacement (ml/rev) System Pressure (MPa) Tank Capacity (L) Solenoid Valve Voltage L (mm)
YBZ5-F2.1B3G2/LBUAN1 220VAC 1.5 1450 2.1 20 5 12VDC 627
YBZ5-F2.7B3G2/LBUBN1 220VAC 1.5 1450 2.7 20 6 24VDC 672
YBZ5-E3.2C3G2/LBUCN1 220VAC 1.5 1450 3.2 16 8 24VAC 777
YBZ5-F2.1C4H2/LCUDN1 380VAC 2.2 2850 2.1 20 8 110VAC 777
YBZ5-F2.7D4H2/LCUEN1 380VAC 2.2 2850 2.7 20 10 220VAC 867
YBZ5-E3.2E4H2/LCUEN1 380VAC 2.2 2850 3.2 16 12 220VAC 887

Remarks

  • Contact our sales engineer for other pump displacements, motor powers, pressures or tank capacities.
  • A manual override function is available on request.
  • 60 Hz motors with CSA or UL certification are available on request.

Precautions

  1. S3 intermittent duty: 1 minute on and 9 minutes off. Continuous operation is not permitted.
  2. Clean all hydraulic components, cylinders, hoses and fittings before installing the power unit.
  3. Use clean hydraulic oil free of impurities, with a viscosity of 15-68 cSt. N46 hydraulic oil is recommended.
  4. Change the hydraulic oil after the first 100 operating hours and every 3,000 hours thereafter.
  5. Mount the power unit horizontally.
PRODUCT INQUIRY

    Product:

    WhatsApp